We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Microwave Level Meter.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Microwave Level Meter - List of Manufacturers, Suppliers, Companies and Products

Microwave Level Meter Product List

1~15 item / All 15 items

Displayed results

[Case Study] Radar Microwave Level Meter for Mobile Trippers

Monitor multiple bunker levels from a mobile tripper! Achieve stable measurements without being affected by dust or steam!

We would like to introduce a case where the radar-type microwave level gauge 'MWLM-PR26H7S' handled by Matsushima Majortech was implemented in a mobile tripper. In the case of laser or ultrasonic types, there was a risk of erroneous measurements due to reflections from dust and steam, and the influence of dust and steam could cause sound waves to attenuate, leading to unstable measurements. By introducing this product, which uses microwaves that have the property of passing through without reflection (noise) from dust and steam, we were able to monitor multiple bunker levels from the mobile tripper. 【Case Study】 ■Challenges - Risk of erroneous measurements due to reflections from dust and steam - Existing level gauges may become unstable due to the influence of dust and steam ■Product Introduced - Radar-type microwave level gauge 'MWLM-PR26H7S' ■Effects - Enabled monitoring of multiple bunker levels from the mobile tripper *For more details, please refer to the PDF document or feel free to contact us.

  • Level gauges and level switches
  • Other measurement, recording and measuring instruments
  • Distance measuring device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Radar-type Microwave Level Meter for Measuring Hot Spring Water Tanks

Measurement even in poor visibility due to steam! Achieving stable measurements in environments where steam and dust are present.

We would like to introduce a case where the radar-type microwave level gauge 'MWLM-PR26H3F' handled by Matsushima Major Tech Co., Ltd. was implemented in a hot spring water tank. The existing ultrasonic level gauge was experiencing measurement errors due to the influence of steam. After installing our product, the measurement errors were eliminated, which was well received. 【Case Study】 ■Challenge - The existing ultrasonic level gauge was experiencing measurement errors due to the influence of steam. ■Product Implemented - Radar-type microwave level gauge 'MWLM-PR26H3F' ■Effect - Measurement errors were eliminated. *For more details, please refer to the PDF document or feel free to contact us.

  • Level gauges and level switches
  • Other measurement, recording and measuring instruments
  • Liquid level control/level switch

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Radar-type Microwave Level Meter for Condensation and Oil Droplet Prevention

Antenna caps for preventing condensation and oil droplets in liquid tanks and oil tanks! Enables stable measurements.

The radar-type microwave level gauge 'MWLM-PR26C1G' handled by Matsushima Majatech features a sensor equipped with a "PTFE antenna cap," and we will introduce a case where it was implemented in an animal fat tank. In some field conditions, condensation and oil droplets may occur. By utilizing the "antenna cap," it prevents the ingress of condensation and oil droplets into the antenna, enabling stable measurements. [Case Study] ■Challenges - Occurrence of condensation and oil droplets ■Product Introduced - Radar-type microwave level gauge 'MWLM-PR26C1G' (PTFE antenna cap) ■Effects - Prevents the ingress of condensation and oil droplets into the antenna, allowing for stable measurements *For more details, please refer to the PDF document or feel free to contact us.

  • Level gauges and level switches
  • Other measurement, recording and measuring instruments
  • Liquid level control/level switch

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Biomass Radar-type Microwave Level Gauge for Chicken Manure Silos

Even in silos with severe material adhesion, effective adhesion prevention measures allow for precise measurement! Cleaning tasks can be reduced!

We would like to introduce a case where the microwave level meter 'MWLM-PR26H7S' handled by Matsushima Majatech was introduced to a biomass plant chicken manure silo. With the existing level meter, there was constant accumulation of deposits even with a cleaning frequency of once a month. However, after switching to this product, the inside of the antenna after three months showed almost no deposits even without cleaning. By utilizing a PTFE-coated antenna, this product reduces deposits and takes advantage of water droplets from condensation to wash away deposits, thereby reducing cleaning work. [Case Study] ■ Issues - The existing level meter had deposits even with a cleaning frequency of once a month. ■ Introduced Product - Microwave level meter 'MWLM-PR26H7S' ■ Effects - Even without cleaning, water droplets were washing away the deposits.

  • Level gauges and level switches
  • Other measurement, recording and measuring instruments
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Corrosion Gas Countermeasure Measuring from the Outside of the Tank - Microwave Level Meter

For the chemical tank that generates corrosive gas, the level is measured from the outside of the resin tank!

We would like to introduce a case study of the radar-type microwave level gauge handled by Matsushima Majotech. In the chemical tank of a factory's wastewater treatment facility, there was a problem where the level gauge corroded due to the influence of chemicals (such as gases). To address this, we utilized the characteristics of microwaves that can penetrate materials with low dielectric constants, allowing us to implement our product to measure from the outside of the tank. 【Case Study】 ■Challenges - Level gauge corrosion due to chemicals ■Product Introduced - Radar-type microwave level gauge 'MWLM-PR26H**' ■Effects - Measurement can now be conducted from the outside of the tank *For more details, please refer to the PDF document or feel free to contact us.

  • Level gauges and level switches
  • Other measurement, recording and measuring instruments
  • Liquid level control/level switch

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Radar Microwave Level Gauge for Wood Chip Chutes

Even if there is only a mounting location on the side wall, it can be measured! Customized with a mounting frame tailored to the equipment!!

We would like to introduce a case study of the radar microwave level gauge 'MWLM-PR26H7S' handled by Matsushima Majortech. There was a problem where there was no installation space above the wood chip chute, making measurement impossible. We fulfilled the request to somehow conduct measurements inside the chute. By installing the level gauge on the side wall and mounting it so that the product faces vertically towards the raw material surface, stable measurements could now be taken from the side. 【Case Study】 ■Challenges - There was no installation space above the wood chip chute, making measurement impossible. ■Product Introduced - Radar microwave level gauge 'MWLM-PR26H7S' ■Effects - Measurements can now be taken from the side.

  • Level gauges and level switches
  • Distance measuring device
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Radar Microwave Level Gauge for Contamination Prevention in Food Factories

Monitor the remaining raw materials in the tank! Eliminate leftover materials to avoid quality defects and quality incidents!

We would like to introduce a case study of the radar-type microwave level gauge 'MWLM-PR26H Series' handled by Matsushima Majatech. In food manufacturing, the mixing of fresh ingredients with old ones can lead to quality accidents. The residual material in the hopper, which causes this issue, cannot be detected by the lower limit switch, so we decided to measure it with a microwave level gauge. 【Case Study】 ■Challenge To prevent contamination, we were visually checking the residual material in the hopper every time we replaced the ingredients. ■Product Introduced Radar-type microwave level gauge 'MWLM-PR26H3S' ■Effect We were able to measure the residual material with the microwave level gauge, eliminating the need for visual confirmation. *For more details, please refer to the PDF document or feel free to contact us.

  • Level gauges and level switches
  • Other measurement, recording and measuring instruments
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Application Example] Proposal for Use in Mining Equipment: "Radar-type Microwave Level Gauge"

It is unaffected by harsh environments such as dust and steam! A level gauge that responds to a sudden 10m level change in 2 seconds.

The radar-type microwave level gauge has excellent tracking capability and is suitable for level control in shafts and detecting blockages in primary crushers. Additionally, since microwaves have the property of penetrating dust and vapor, there is no risk of mistakenly measuring dust or vapor. 【Features】 ■ Improved tracking capability ■ Not affected by dust or vapor ■ Not affected by wind, temperature, or gas *For more details, please refer to the PDF document or feel free to contact us.

  • Level gauges and level switches

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study Collection] Microwave Level Measurement for Factory and Plant Applications

Numerous examples of level measurement achieved in harsh environments such as high temperatures, foamy liquid surfaces, condensation, oil droplets, and corrosive gases are featured!

Level measurement is essential in factories and plants, but there are still many challenges in measuring levels in various harsh environments. If these issues remain unresolved, it can lead to inaccurate measurements and equipment damage. Matsushima Majatech, as a manufacturer of level measurement devices, has addressed various measurement challenges, including those related to powders. This document is a collection of case studies featuring the introduction of radar microwave level meters handled by Matsushima Majatech. It includes examples such as the "Wood Chip Chute Introduction Case," which can measure even when there is only wall space available, the "Chicken Manure Silo Introduction Case," which prevents adhesion and reduces cleaning work, and the "Mobile Tripper Introduction Case." Each case highlights key points and is presented with photos and illustrations. [Featured Case Studies (Excerpt)] ■ Wood Chip Chute Introduction Case ■ Chicken Manure Silo Introduction Case ■ Mobile Tripper Introduction Case ■ Mining Plant Introduction Case ■ Beverage Plant Introduction Case *For more details, please refer to the PDF document or feel free to contact us.

  • Liquid level control/level switch

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] High-Temperature Equipment Radar Microwave Level Gauge for Sintering Coolers

Proven in the high-temperature environment of steel mills! Monitoring layer thickness for process control! For controlling input amounts and detecting blockages!

We would like to introduce a case study of the "Radar Microwave Level Meter" handled by Matsushima Majatech, which has been implemented in sintering equipment (sintering cooler). This product monitors the thickness of the sintered ore layer for process control and checks the levels after feeding and discharging. It avoids heat sources with an L-shaped waveguide antenna and cools the antenna with purging. A heat shield prevents dust from entering the antenna, stabilizing measurement performance. Please use it for controlling input amounts and detecting blockages. 【Case Study】 ■ Installation Site - Sintering Equipment (Sintering Cooler) ■ Installed Product - "Radar Microwave Level Meter"

  • Level gauges and level switches
  • Other measurement, recording and measuring instruments
  • Distance measuring device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Radar-type Microwave Level Gauge for Corrosion Prevention Liquid Level Measurement

An optional PTFE antenna cap protects the antenna from corrosive gases!

We would like to introduce a case where the "Radar Microwave Level Meter" handled by Matsushima Majortech was implemented in a chemical tank. The gas contact part of this product is made of "SUS304." However, if there is still a possibility of corrosion, attaching the optional "PTFE Antenna Cap" to the antenna will prevent corrosive gases from entering and protect the antenna from corrosion. 【Case Study】 ■ Installation Location - Chemical Tank ■ Installed Product - "Radar Microwave Level Meter" + "PTFE Antenna Cap" * Limited to specific models * For more details, please refer to the PDF document or feel free to contact us.

  • Level gauges and level switches
  • Liquid level control/level switch
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Radar-type Microwave Level Gauge for Liquid Level (Foam Countermeasure) Measurement

Even when a large amount of foam is generated during liquid level measurement in the tank, measurement is possible! Stable measurement is achieved using a guide pipe.

We would like to introduce a case study of the radar-type microwave level gauge handled by Matsushima Majatech. There was a problem of false detection due to the influence of bubbles when detecting the liquid level in the container. To address this, we installed a "guide pipe" and introduced our product. Even when bubbles occur at the liquid surface, they do not enter the pipe, allowing for measurement of only the liquid level. 【Case Study】 ■Challenge - False detection occurs due to the influence of bubbles when detecting the liquid level in the container. ■Product Introduced - Radar-type microwave level gauge 'MWLM-PR26H2F' + "Guide Pipe" ■Effect - Even when bubbles occur at the liquid surface, they do not enter the pipe, allowing for measurement of only the liquid level. *For more details, please refer to the PDF document or feel free to contact us.

  • Level gauges and level switches
  • Other measurement, recording and measuring instruments
  • Liquid level control/level switch

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【Product PR】Evolved and making a comeback! Radar-type microwave level gauge

Redesign by focusing on what is necessary now and what can be done now. Measurement accuracy has increased by more than twice!

Six years since its release, the radar-type microwave level gauge has, thanks to you, been utilized by many customers. However, there have been applications where we were unable to meet customer demands. What is needed to realize that? We will focus on what is necessary now and what can be done now to redesign. In May 2018, the "Microwave Level Gauge" will make its re-debut with an upgraded version while maintaining the same appearance. 【Overview of Version 2.0】 ■ Improved accuracy ■ Enhanced tracking performance ■ Increased resolution ■ Improved noise tolerance ■ Increased power supply tolerance ■ Extended wiring distance *For more details, please refer to the PDF document or feel free to contact us.

  • Level gauges and level switches
  • Other measurement, recording and measuring instruments
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Microwave Level Measurement and Wireless Management System

Eliminate daily measurement work to zero!

Customer Information Delivery Destination: Cement Service Station Installed Equipment: Microwave Level Gauge + Wireless Monitoring System Results: Improved Safety and Reduced Work Time Challenges Before Implementation Every day, we had to climb the silo to perform measurement work at heights. It was a time-consuming task, and we also had to pay attention to safety. For more details, please refer to the related link URL.

  • Level gauges and level switches
  • Distance measuring device
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Reducing Unnecessary Tasks! Radar Microwave Level Meter

Nationwide Cement Service Stations Reduce Unnecessary Work!

Utilizing microwave level gauges, we solved issues such as inventory discrepancies and maintenance burdens at large silos in cement service stations nationwide. [Challenges] - Contact-type level gauges require cumbersome maintenance - Level switches cause discrepancies in inventory, making precise management of receiving and dispatching difficult For more details, please refer to the related link URL.

  • Level gauges and level switches
  • Distance measuring device
  • Liquid Level Sensor

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration